General Description

The Shure Audio Network Interface converts 4 channels of Dante™ digital audio into discrete analog signals. Connect to a processing device with analog connections (audio processors, video codecs, and loudspeaker systems, for example) to fully integrate networked audio and analog equipment in a single system. Available in XLR and block connector versions, each box uses a single network cable to receive audio and power through Power over Ethernet (PoE).

Model Variations

ANI4OUT-XLR: Four XLR outputs (balanced audio)

ANI4OUT-BLOCK: Four 3-pin block connector outputs (balanced audio)

Hardware

Block Connector Model

Front Panel

XLR Model

Rear Panel

Front Panel

① Output Level Indicators (Signal/Clip)

Tri-color LEDs indicate the audio signal level for each channel. Adjust levels in the web application to avoid clipping.

LED State Audio Signal Level
Off less than -60 dBFS
Green -60 dBFS to -18 dBFS
Yellow -18 dBFS to -6 dBFS
Red -6 dBFS or more

② Audio Outputs

Analog balanced audio outputs connect to an analog device. Set the output level in the web application to match the input sensitivity of the analog device.

XLR pin assignments:

1 Shield
2 +
3 -

Block connector pin assignments: See front panel labels

③ Chassis Ground Screw

Provides an optional connection for microphone shield wire to chassis ground

Note: only applies to block connector version

④ LED Indicators

Power: Power over Ethernet (PoE) present

Note: Note: Use a PoE injector if your network switch does not supply PoE.

Network: Network connection active

Network Audio: Dante audio present on the network

Note: Error details are available in the event log in the web application.

Encryption: Not currently supported

LED Status Activity
Off No active signal
Green Device is operating successfully
Red Error has occurred. See event log for details.

⑤ Dante Network Port

Connects to a network switch to receive Dante audio, Power over Ethernet (PoE), and data from the control software.

⑥ Reset Button

Resets the device settings back to the factory default

Installation and Rack Mounting

Two mounting solutions are available for installing the Audio Network Interface:

CRT1 19" Rack Tray (optional accessory): Supports up to 3 devices; mountable in a rack or under a table

Single-unit Mounting Tray (included accessory): Supports a single device for mounting under a table

Securing the Devices

Use the included screws from the mounting hardware kit to secure the Audio Network Interfaces. Audio Network Interfaces can be mounted to face either direction. Insert the screws from the bottom in the appropriate holes, according to the following diagrams:

Align the holes as shown for securing a single device in the single-unit mounting tray

Align the holes as shown for securing up to three devices in the 19" rack tray.

Rack Ear Configuration

A combination of up to 3 Audio Network Interfaces can be mounted in a single 19-inch rack space. The adjustable rack ears support mounting in a standard equipment rack or underneath a table.

Standard 19" Rack Mount

  1. Align the ears with the mounting holes pointed forward.
  2. Install the two screws that hold the ear to the tray as shown.

Under-table Mounting

  1. Align the ears with the mounting holes pointed upward.
  2. Install the two screws that hold the ear to the tray as shown.

Installing Underneath a Table

  1. Hold the tray in the desired location under a table
  2. Use a pencil to mark the location of the mounting holes on the table.
  3. Drill 4 holes for the screws. The diameter of the holes in the tray are 7.1 mm.
  4. Install the components into the tray
  5. Install with 4 screws to secure the tray underneath the table

乙太網路供電 (PoE)

本裝置需要 PoE 才能工作。它與 0 類 3 類 PoE 源均相容。

乙太網路供電的工作方式如下:

  • 一台提供 PoE 的網路交換機
  • 一個 PoE 注射裝置

Reset

The reset button is located inside a small hole in the front panel. Use a paperclip or other small tool to press the button.

There are two reset functions:

Network reset (press button for 4-8 seconds)

Resets all Shure control and audio network IP settings to factory defaults

Full factory reset (press button for longer than 8 seconds)

Restores all network and web application settings to the factory defaults.

Connections and Signal Flow

Input: Dante Digital Audio

A single network cable delivers 4 channels of audio and Power over Ethernet (PoE). Use Dante Controller to route audio channels from the network to the network interface.

Output: Analog (4 XLR or Block Connectors)

Each output sends a discrete audio channel to connect to an analog device.

Setting up the Audio Network

Shure networked conferencing systems are comprised of Microflex Advance microphones and network interfaces, which operate entirely on a Dante network. Additional hardware, including network switches, computers, loudspeakers, and audio processors are described in the hardware component index.

Shure components shown in this diagram:

Microflex Advance Microphones

The MXA910 and MXA310 are equipped with Dante outputs, and connect directly to a network switch.

Audio Network Interfaces

The interfaces are used to connect analog devices such as loudspeakers and analog microphones to the network.

ANI4IN: Converts 4 analog signals (separate XLR and block connector models available) into Dante digital audio signals.

ANI4OUT: Converts 4 channels of Dante audio from the network into analog signals.

This diagram shows the entire signal path through a networked conference system. Signals from the near end and far end are exchanged through an audio processor connected to a phone system, or through a computer connected to the internet. Analog microphones connect to the network through the Shure ANI4IN, while loudspeakers connect through the Shure ANI4OUT.

This diagram shows Microflex Advance components in context, with two rooms communicating through video codecs.

Controlling Hardware and Audio Over the Network

Audio and hardware settings are managed through a computer connected to the same network.

Shure Hardware and Audio

Each Microflex Advance component has a web application which provides mixing and configuration tools to optimize sound quality.

Expanded Control for Analog Devices

Analog devices that are connected to the network through a Shure network interface (ANI4IN/ANI4OUT) benefit from additional remote control: Volume levels, equalization, and signal routing are managed through the web application. For example, adjusting loudspeaker volume or muting a wired microphone, which would normally be done from the hardware, can now be controlled remotely over the network.

Dante Signal Routing

Signal routing between devices is managed through Dante Controller software, provided by Audinate™.

Summing

The Audio Network Interface provides channel summing to combine Dante signals from the network, and send them over a single analog output. This makes it possible to send all channels to a device with a limited amount of analog input channels. Mixer functionality does not change; audio channels are simply sent as one combined signal.

Note: When summing is enabled, a limiter is activated to prevent signal overloading. The limiter never applies to the direct outputs, and only affects the summed signal.

To enable, select one of the summing options in the toolbar at the top of the mixer in the channels tab.

Using the Software

軟體安裝和裝置發現

Shure Web Device Discovery 應用程式用於存取適用於 Shure 裝置的 網頁應用程式 。如果加密設定不同,將在接收機液晶顯示面板上顯示 網頁應用程式 可以在網路瀏覽器中開啟,提供綜合的裝置管理手段。和裝置聯網的任何電腦均可透過該應用存取 GUI。

相容瀏覽器:

  • Chrome
  • Safari
  • Firefox
  • Internet Explorer
  1. 安裝 Shure Web Device Discovery 應用程式,該程式可從 www.shure.com 取得
  2. 按兩下元件以開啟介面。

存取 網頁應用程式

Shure Web Server Discovery 應用程式可透過基於 Web 的圖表化使用者介面搜尋網路中的所有舒爾裝置。執行這些步驟,安裝軟體並存取 網頁應用程式

① 安裝 Shure Discovery 應用程式

從 www.shure.com 下載並安裝 Shure Discovery 應用程式。這樣可以在電腦上自動安裝所需的 Bonjour 裝置檢測工具。

② 連接網路

確保電腦和硬體位於相同的網路中。

③ 啟動 Discovery 應用程式

應用程式將顯示採用圖表化使用者介面的所有舒爾裝置。

④ 識別硬體

按兩下裝置可在網路瀏覽器中開啟圖表化使用者介面 (GUI)。

⑤ 給裝置設定標籤 網頁應用程式 (建議)

將裝置的 DNS 名稱加入書籤,可以在不需要 Shure Discovery 應用程式的情況下存取圖表化使用者介面。

Accessing the Web Application without the Discovery App

If the Discovery application is not installed, the web application can be accessed by typing the DNS name into an internet browser. The DNS name is derived from model of the unit, in combination with the last three bytes (six digits) of the MAC address, and ending in .local.

Format Example: If the MAC address of a unit is 00:0E:DD:AA:BB:CC, then the link is written as follows:

ANI4IN: http://ANI4IN-aabbcc.local

ANI4OUT: http://ANI4OUT-aabbcc.local

固件更新

固件是在每個功能控制元件中的嵌入式軟體。定期開發的新固件版本中包含附加功能和效能增強部分。若要享受設計改進帶來的優勢,可利用「Shure Update Utility」工具上傳和安裝新版本的固件。軟體可以從網站 http://www.shure.com 中下載。

重要提示:透過 Shure MXW 音訊網路介面連接 Shure Olympus 元件時,它們的固件必須在更新 MXW 音訊網路介面固件之前在一台裝置上進行更新。嘗試同時更新所有裝置將導致介面在固件更新後重新啟動,將遺失與其他聯網元件的連接。

按照以下步驟更新固件:

小心!確保裝置在更新期間具有穩定的網路連接。在完成更新之前,請勿關閉裝置電源。

  1. 將裝置和電腦接入同一網路(設為相同子網)。
  2. 下載和安裝 Shure Update Utility。
  3. 開啟應用程式。
  4. 按一下 Check For Updates... 檢視可供下載的新固件版本。
  5. 選擇所需的固件,按Download下載至固件庫中。
  6. Update Devices標籤中選擇新固件,然後按下Send Updates...開始固件更新,這會重寫裝置現有固件。

固件版本要求

透過 Shure MXW 裝置採用多通訊協定的網路,這些協定同時確保裝置正常工作。推薦的最佳做法是所有 透過 Shure MXW 裝置採用相同的版本。若要檢視網路中每個裝置的固件版本,可開啟元件使用者介面,然後查看 Settings > About .

Shure 裝置的固件格式為 MAJOR.MINOR.PATCH。(例如在固件「1.6.2」中,1 為主要固件等級,6 為次要固件等級,2 為補丁固件等級。)在相同子網工作的裝置至少應擁有相同主要和次要版本號。

  • 主要版本號不同的裝置不相容。
  • 補丁固件版本號的差異可能會產生不希望出現的不一致性。

Parametric Equalizer

Maximize audio quality by adjusting the frequency response with the parametric equalizer.

Common equalizer applications:

  • Improve speech clarity
  • Reduce noise from HVAC systems or video projectors
  • Reduce room irregularities
  • Adjust frequency response for reinforcement systems

Setting Filter Parameters

Adjust filter settings by manipulating the icons in the frequency response graph, or by entering numeric values. Disable a filter using the check-box next to the filter.

Filter Type

Only the first and last band have selectable filter types.

Parametric: Attenuates or boosts the signal within a customizable frequency range

Low Cut: Rolls off the audio signal below the selected frequency

Low Shelf: Attenuates or boosts the audio signal below the selected frequency

High Cut: Rolls off the audio signal above the selected frequency

High Shelf: Attenuates or boosts the audio signal above the selected frequency

Frequency

Select the center frequency of the filter to cut/boost

Gain

Adjusts the level for a specific filter (+/- 30 dB)

Q Width

Adjusts the range of frequencies affected by the filter. As this value increases, the bandwidth becomes thinner.

Equalizer Applications

Conferencing room acoustics vary based on room size, shape, and construction materials. Use the guidelines in following table.

EQ Application Suggested Settings
Treble boost for improved speech intelligibility Add a high shelf filter to boost frequencies greater than 1 kHz by 3-6 dB
HVAC noise reduction Add a low cut filter to attenuate frequencies below 200 Hz
Reduce flutter echoes and sibilance Identify the specific frequency range that "excites" the room:
  1. Set a narrow Q value
  2. Increase the gain to between +10 and +15 dB, and then experiment with frequencies between 1 kHz and 6 kHz to pinpoint the range of flutter echoes or sibilance
  3. Reduce the gain at the identified frequency (start between -3 and -6 dB) to minimize the unwanted room sound
Reduce hollow, resonant room sound Identify the specific frequency range that "excites" the room:
  1. Set a narrow Q value
  2. Increase the gain to between +10 and +15 dB, and then experiment with frequencies between 300 Hz and 900 Hz to pinpoint the resonant frequency
  3. Reduce the gain at the identified frequency (start between -3 and -6 dB) to minimize the unwanted room sound

Event Log

The event log provides a detailed account of activity from the moment the device is powered on. The log collects up to 1,000 activity entries and time-stamps them relative to the last power cycle.

To troubleshoot audio or hardware problems, save the log using the export button. Refer to the log file for details when troubleshooting or consulting with Shure Systems Support.

To view the event log:

  1. Open the Help menu
  2. Select View Event Log

Severity Level

Information

An action or event has been successfully completed

Warning

An action cannot be complete, but overall functionality is stable

Error

A problem has occurred that could inhibit functionality.

Tip: Use the filter to narrow down results.

Adjusting Input levels

  1. Check the source level before it reaches the Network Interface:
    • Verify that the networked microphones or other Dante sources are operating at nominal output levels.
    • Levels for Microflex Advance™ microphones are adjustable through their web application.
  2. Adjust the digital gain in the Network Interface web application:
    • Use the faders or manually enter a gain value.
    • The digital gain adjusts the level of the signal before it reaches the analog circuitry.
    • Set these levels as high as possible without reaching the peak level (0 dB) on the meter.

Adjusting Output Levels

Access the analog output levels through the web application, by selecting an output level from the Analog Gain (dB) pull-down menu. Match the output level from the Network Interface to the input sensitivity on the analog device:

  • Line level (0 dB)
  • Aux level (-27 dB)
  • Microphone level (-45 dB)

LED Signal and Clipping Indicators

Each analog output channel has a corresponding LED:

Green: Audio signal present

Red: Audio signal is clipping and should be attenuated.

Note: the meters in the web application are not affected by the Analog Gain (dB) setting.

Pre- and Post-Fader Metering

There are two modes for monitoring so that both the input and output signals can be monitored separately.

When set to pre-fader, the meter displays the signal level from the source on the Dante network. If signals are too low or clipping, adjust them at the source.

When set to post-fader, the meter is affected by the digital gain. It is not affected by the output analog gain setting.

ANI4OUT Command Strings

This document can also be found at: http://shure.custhelp.com/app/answers/detail/a_id/6060

The device is connected via Ethernet to a control system, such as AMX, Crestron or Extron.

Connection: Ethernet (TCP/IP; select “Client” in the AMX/Crestron program)

Port: 2202

Conventions

The device has 4 types of strings:

GET

Finds the status of a parameter. After the AMX/Crestron sends a GET command, the ANI4OUT responds with a REPORT string

SET

Changes the status of a parameter. After the AMX/Crestron sends a SET command, the ANI4OUT will respond with a REPORT string to indicate the new value of the parameter.

REP

When the ANI4OUT receives a GET or SET command, it will reply with a REPORT command to indicate the status of the parameter. REPORT is also sent by the ANI4OUT when a parameter is changed on the ANI4OUT or through the GUI.

SAMPLE

Used for metering audio levels.

All messages sent and received are ASCII. Note that the level indicators and gain indicators are also in ASCII

Most parameters will send a REPORT command when they change. Thus, it is not necessary to constantly query parameters. The ANI4OUT will send a REPORT command when any of these parameters change.

The character “x” in all of the following strings represents the channel of the ANI4OUT and can be ASCII numbers 0 through 4 as in the following table

0 All channels
1 through 4 Individual channels

Command Strings (Common)

Get All
Command String:

< GET x ALL >

Where x is ASCII channel number: 0 through 4. Use this command on first power on to update the status of all parameters.
ANI4OUT Response:

< REP ... >

The ANI4OUT responds with individual Report strings for all parameters.
Get Channel Name
Command String:

< GET x CHAN_NAME

Where x is ASCII channel number: 0 through 4.
ANI4OUT Response:

< REP x CHAN_NAME {yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy} >

Where yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy is 31 characters of the user name. The ANI4OUT always responds with a 31 character name.
Get Device ID
Command String:

< GET DEVICE_ID >

The Device ID command does not contain the x channel character, as it is for the entire ANI4OUT.
ANI4OUT Response:

< REP DEVICE_ID {yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy} >

Where yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy is 31 characters of the device ID. The ANI4OUT always responds with a 31 character device ID.
Get Preset
Command String:

< GET PRESET >

ANI4OUT Response:

< REP PRESET nn >

Where nn is the preset number 01-10.
Set Preset
Command String:

< SET PRESET nn >

Where nn is the preset number 1-10. (Leading zero is optional when using the SET command).
ANI4OUT Response:

< REP PRESET nn >

Where nn is the preset number 01-10.
Get Preset Name
Command String:

< GET PRESET1 >

< GET PRESET2 >

< GET PRESET3 >

etc

Send one of these commands to the ANI4OUT
ANI4OUT Response:

< REP PRESET1 {yyyyyyyyyyyyyyyyyyyyyyyyy} >

< REP PRESET2 {yyyyyyyyyyyyyyyyyyyyyyyyy} >

< REP PRESET3 {yyyyyyyyyyyyyyyyyyyyyyyyy} >

etc

Where yyyyyyyyyyyyyyyyyyyyyyyyy is 25 characters of the device ID. The ANI4OUT always responds with a 25 character device ID
Get Audio Gain
Command String:

< GET x AUDIO_GAIN_HI_RES >

Where x is ASCII channel number: 1 through 4.
ANI4OUT Response:

< REP x AUDIO_GAIN_HI_RES yyyy >

Where yyyy takes on the ASCII values of 0000 to 1400. yyyy is in steps of one-tenth of a dB.
Set Audio Gain
Command String:

< SET x AUDIO_GAIN_HI_RES yyyy >

Where yyyy takes on the ASCII values of 0000 to 1400. yyyy is in steps of one-tenth of a dB.
ANI4OUT Response:

< REP x AUDIO_GAIN_HI_RES yyyy >

Where yyyy takes on the ASCII values of 0000 to 1400.
Increase Audio Gain by n dB
Command String:

< SET x AUDIO_GAIN_HI_RES INC nn >

Where nn is the amount in one-tenth of a dB to increase the gain. nn can be single digit ( n ), double digit ( nn ), triple digit ( nnn ).
ANI4OUT Response:

< REP x AUDIO_GAIN_HI_RES yyyy >

Where yyyy takes on the ASCII values of 0000 to 1400.
Decrease Audio Gain by n dB
Command String:

< SET x AUDIO_GAIN_HI_RES DEC nn >

Where nn is the amount in one-tenth of a dB to decrease the gain. nn can be single digit ( n ), double digit ( nn ), triple digit ( nnn ).
ANI4OUT Response:

< REP x AUDIO_GAIN_HI_RES yyyy >

Where yyyy takes on the ASCII values of 0000 to 1280.
Get Channel Audio Mute
Command String:

< GET x AUDIO_MUTE >

Where x is ASCII channel number: 0 through 4.
ANI4OUT Response:

< REP x AUDIO_MUTE ON >

< REP x AUDIO_MUTE OFF >

The ANI4OUT will respond with one of these strings.
Mute Channel Audio
Command String:

< SET x AUDIO_MUTE ON >

ANI4OUT Response:

< REP x AUDIO_MUTE ON >

Unmute Channel Audio
Command String:

< SET x AUDIO_MUTE OFF >

ANI4OUT Response:

< REP x AUDIO_MUTE OFF >

Toggle Channel Audio Mute
Command String:

< SET x AUDIO_MUTE TOGGLE >

ANI4OUT Response:

< REP x AUDIO_MUTE ON >

< REP x AUDIO_MUTE OFF >

The ANI4OUT will respond with one of these strings.
Get Analog Gain
Command String:

< GET x AUDIO_OUT_LVL_SWITCH >

Where x is ASCII channel number: 0 through 4.
ANI4OUT Response:

< REP x AUDIO_OUT_LVL_SWITCH LINE_LVL >

< REP x AUDIO_OUT_LVL_SWITCH AUX_LVL >

< REP x AUDIO_OUT_LVL_SWITCH MIC_LVL >

The ANI4OUT will respond with one of these strings.
Set Analog Gain
Command String:

< SET x AUDIO_OUT_LVL_SWITCH LINE_LVL >

< SET x AUDIO_OUT_LVL_SWITCH AUX_LVL >

< SET x AUDIO_OUT_LVL_SWITCH MIC_LVL >

Where x is ASCII channel number: 0 through 4. Send one of these commands to the ANI4OUT.
ANI4OUT Response:

< REP x AUDIO_OUT_LVL_SWITCH LINE_LVL >

< REP x AUDIO_OUT_LVL_SWITCH AUX_LVL >

< REP x AUDIO_OUT_LVL_SWITCH MIC_LVL >

The ANI4OUT will respond with one of these strings.
Get Sig/Clip LED
Command String:

< GET x LED_COLOR_SIG_CLIP >

Where x is ASCII channel number: 0 through 4. It is not necessary to continually send this command. The ANI4OUT will send a REPORT message whenever the status changes.
ANI4OUT Response:

< REP x LED_COLOR_SIGL_CLIP OFF >

< REP x LED_COLOR_SIG_CLIP GREEN >

< REP x LED_COLOR_SIG_CLIP AMBER >

< REP x LED_COLOR_SIG_CLIP RED >

The ANI4OUT will respond with one of these strings. This matches the sig/clip LEDs on the front of the ANI4OUT.
Flash Lights on ANI4OUT
Command String:

< SET FLASH ON >

< SET FLASH OFF >

Send one of these commands to the ANI4OUT. The flash automatically turns off after 30 seconds.
ANI4OUT Response:

< REP FLASH ON >

< REP FLASH OFF >

The ANI4OUT will respond with one of these strings.
Turn Metering On
Command String:

< SET METER_RATE sssss >

Where sssss is the metering speed in milliseconds. Setting sssss=0 turns metering off. Minimum setting is 100 milliseconds. Metering is off by default.
ANI4OUT Response:

< REP METER_RATE sssss >

< SAMPLE aaa bbb ccc ddd >

Where aaa, bbb, etc is the value of the audio level received and is 000-060.

aaa = output 1

bbb = output 2

ccc = output 3

ddd = output 4

Stop Metering
Command String:

< SET METER_RATE 0 >

A value of 00000 is also acceptable.
ANI4OUT Response:

< REP METER_RATE 00000 >

Get LED Brightness
Command String:

< GET LED_BRIGHTNESS >

ANI4OUT Response:

< REP LED_BRIGHTNESS n >

Where n can take on the following values:

0 = LED disabled

1 = LED dim

2 = LED default

Set LED Brightness
Command String:

< SET LED_BRIGHTNESS n >

Where n can take on the following values:

0 = LED disabled

1 = LED dim

2 = LED default

ANI4OUT Response:

< REP LED_BRIGHTNESS n >

Dante & Networking

數字式音訊網路

Dantetm 數字音訊訊號是透過標準乙太網路傳輸的,使用標準的網路通訊協定工作。Dante 具有低延遲、緊密時鐘同步和高品質服務 (QoS) 等功能,從而為各種 Dante 裝置提供可靠的音訊廣播。Dante 音訊可以與 IT 和控制資料在相同網路中安全共存,也可以設定為使用私人網路絡。

適用於 Dante 網路的交換機建議

除了基本聯網要求以外,Dante 音訊網路應使用具有下列功能的千兆乙太網路交換機或路由器:

  • 千兆乙太網路埠
  • 可容納 4 個佇列的品質服務 (QoS)
  • 採用嚴格優先順序的 Diffserv (DSCP) QoS
  • 推薦使用:受管理客戶機能夠提供有關每個網路連接的詳細資訊(埠速度、錯誤技術、佔用頻寬)

QoS (Quality of Service) Settings

QoS settings assign priorities to specific data packets on the network, ensuring reliable audio delivery on larger networks with heavy traffic. This feature is available on most managed network switches. Although not required, assigning QoS settings is recommended.

Note: Coordinate changes with the network administrator to avoid disrupting service.

To assign QoS values, open the switch interface and use the following table to assign Dante-associated queue values.

  • Assign the highest possible value (shown as 4 in this example) for time-critical PTP events
  • Use descending priority values for each remaining packet.

Dante QoS Priority Values

Priority Usage DSCP Label Hex Decimal Binary
High (4) Time-critical PTP events CS7 0x38 56 111000
Medium (3) Audio, PTP EF 0x2E 46 101110
Low (2) (reserved) CS1 0x08 8 001000
None (1) Other traffic BestEffort 0x00 0 000000

Note: Switch management may vary by manufacturer and switch type. Consult the manufacturer's product guide for specific configuration details.

For more information on Dante requirements and networking, visit www.audinate.com.

Networking Terminology

PTP (Precision Time Protocol): Used to synchronize clocks on the network

DSCP (Differentiated Services Code Point): Standardized identification method for data used in layer 3 QoS prioritization

Dante Transmit Flows

For each device, there is a limit of two transmit flows and two receive flows. A single flow consists of up to four channels, through either a unicast or multicast transmission.

  • A unicast flow is a point-to-point connection between two devices, supporting up to four channels per flow.
  • A multicast flow is a one-to-many transmission, which supports sending up to four channels to multiple receiving devices across the network.

Shure Device Applications

Each Shure device can connect with up to two Dante devices.

The Shure MXA310 and ANI4IN support multicast transmission. This means that flows can transmit to multiple devices -- as many as the network can support. If using unicast flows, each Shure device can connect with up to two Dante receiver devices.

The Shure ANI4OUT connects with up to two Dante transmitter devices.

重要產品資訊

此設備用於專業音響場合。

注意:不能將本設備直接連接到公眾互聯網。

EMC 符合環境 E2:商業和輕工業。測試是使用所提供和推薦的纜線類型完成的。使用其它無遮罩的纜線類型可能會降低 EMC 效能。

未經舒爾公司明確許可的修改或改裝會使您操作本設備的授權失效。

加拿大工業部 ICES-003 合規標籤:CAN ICES-3 (B)/NMB-3(B)

符合美國聯邦通訊委員會法規第 15B 章的要求。

請遵循您所在地的電池、包裝和電子廢棄物回收標準。

用戶資訊

本設備已經過測試,符合 FCC 法規第 15 章有關 B 類數位設備的限制。這些限制專適用於在住宅內安裝此設備,能夠為用戶提供免受有害幹擾影響的足夠保護。本設備產生、使用並可能發射無線電頻率能量,如果沒有按照要求安裝和使用設備,可能會對無線電通訊產生有害幹擾。但是,並不保證本設備在特定的安裝情況下不產生幹擾。如果本設備確實對收音機或電視機的接收產生有害幹擾,可以通過關閉本設備然後再打開的方法來確定幹擾,建議用戶通過以下一種或多種方法自行排除此幹擾。

  • 調整接收天線的方向或位置。
  • 增大設備和接收機之間的距離。
  • 將設備連接到與接收機不同的電路插座。
  • 可以向經銷商或有經驗的無線電/電視工程師咨詢以尋求幫助。

可從以下地址獲得“CE 符合性聲明”: www.shure.com/europe/compliance

歐盟授權代表:

Shure Europe GmbH

歐洲、中東、非洲總部

部門:歐洲、中東、非洲批准部

Jakob-Dieffenbacher-Str.12

75031 Eppingen, Germany

電話:49-7262-92 49 0

傳真:49-7262-92 49 11 4

Email: info@shure.de

本產品符合所有相關歐盟法規的基本要求,並且允許使用 CE 標誌。

可從舒爾公司或其任何歐洲代表處獲得“歐盟符合性聲明”。 有關聯繫資訊,請存取 www.shure.com

規格

輸入

(1) RJ45

輸出

ANI4OUT-XLR (4) XLR 接頭
ANI4OUT-BLOCK (4) XXXXERROR: [[ 3-pin block connector ]] DOES NOT EXISTXXXX

設定

XXXXERROR: [[ Impedance Balanced ]] DOES NOT EXISTXXXX

極性

非倒相,任何輸入至任何輸出

電源要求

乙太網供電 (PoE), 0 類

功率消耗

10W, 最大值

重量

663  克 (1.5 磅)

外觀尺寸

高度 x 寬度 x 深度

4 x 14 x 12.8 釐米 (1.6 x 5.5 x 5.0 英寸)

控制應用程式

HTML5 基於瀏覽器

工作溫度範圍

−6.7°C (20°F) 到 40°C (104°F)

存儲溫度範圍

−29°C (-20°F) 到 74°C (165°F)

音訊

頻率響應

20 到 20,000 赫茲

輸入 (Dante 數位音訊)

頻道數 4
採樣率 48 千赫
位深度 24

延遲

Does not include Dante latency

0.71 毫秒

動態範圍 (Dante 至類比)

20 赫茲至 20 千赫, A-加權, 典型

117 dB

總諧波失真

@ 1 千赫, -20 XXXXERROR: [[ dBFS ]] DOES NOT EXISTXXXX 輸出, 0 dB XXXXERROR: [[ analog gain ]] DOES NOT EXISTXXXX

<0.05%

輸出 削波電平

Line(線路) +20 dBV
Aux(輔助) +0 dBV
話筒 -26 dBV

XXXXERROR: [[ Analog Output Level ]] DOES NOT EXISTXXXX

可選擇 Line(線路) 0 dB
Aux(輔助) - 20 dB
話筒 -46 dB

輸出阻抗

150 Ω

內置 數字訊號處理

每頻道 等化器 (4 波段參數), 靜音, XXXXERROR: [[ invertPolarity ]] DOES NOT EXISTXXXX, 增益位置 (140 dB 範圍)
系統 XXXXERROR: [[ Audio Summing ]] DOES NOT EXISTXXXX

連網

纜線要求

Cat 5e 或更高規格 (建議採用遮罩線)

IP Ports and Protocols

Shure Control

Port TCP/UDP Protocol Description Factory Default
21 tcp FTP Required for firmware updates (otherwise closed) Closed
22 tcp SSH Not supported Closed
23 tcp Telnet Standard console interface Closed
68 udp DHCP Dynamic Host Configuration Protocol Open
80* tcp HTTP Required to launch embedded web server Open
427 tcp/udp SLP Required for inter-device communication Open
443 tcp HTTPS Not supported Closed
161 tcp SNMP Not supported Closed
162 tcp SNMP Not supported Closed
2202 tcp ASCII Required for 3rd party control strings Open
5353 udp mDNS Required for device discovery Open
5568 udp SDT Required for inter-device communication Open
8023 tcp Telnet Debug console interface Password
8180* tcp HTML Required for 網頁應用程式 Open
8427 udp Multcast SLP Required for inter-device communication Open
64000 tcp Telnet Required for Shure firmware update Open

Dante Audio & Controller

Port TCP/UDP Protocol Description
162 udp SNMP Used by Dante
[319-320]* udp PTP Dante clocking
4321, 14336-14600 udp Dante Dante audio
[4440, 4444, 4455]* udp Dante Dante audio routing
5353 udp mDNS Used by Dante
[8700-8706, 8800]* udp Dante Dante Control and Monitoring
8751 udp Dante Dante Controller
16000-65536 udp Dante Used by Dante

*These ports must be open on the PC or control system to access the device through a firewall.

These protocols require multicast. Ensure multicast has been correctly configured for your network.

附件

提供的附件

Hardware kit (XLR model)

90A29254

Hardware kit (block connector model)

90A29252

Mounting Bracket (1/3 rack unit)

53A27742

選配附件和替換部件

19" rack tray

CRT1