This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. |
![]() |
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. |
WARNING: Danger of explosion if incorrect battery replaced. Operate only with AA batteries.
Note: Use this battery charger only with the Shure Model PS51 series power supply.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Industry Canada ICES-003 Compliance Label: CAN ICES-3 (B)/NMB-3(B)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation of this device is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
The SBC210 charging station charges SB900 batteries in a convenient and compact desktop unit.
① Charger Housing |
|
② 2-Bay Charging Module |
|
③ Installation Screws (4 pieces) |
|
④ Power LED |
|
⑤ Charge Status LED |
|
⑥ Charging Bay |
|
⑦ DC Power Supply Input |
|
⑧ Lock Switch |
|
⑨ Bay Door |
2-bay charging module | SBC-AX |
Power Supply | PS51 |
Mounting Screws for Charger Modules (8) | 30B13476 |
To Insert:
To Remove:
Slide tab to the right and open battery door. Remove battery from charger.
Slide the battery into the charging bay. Charging begins as soon as the charger door is closed and locked into place.
Each charger bay has an LED to indicate the status of the battery.
Red |
battery charging |
Green |
charging complete |
Off |
battery inserted incorrectly or battery depleted below 3.0 volts. |
Amber |
charging stopped at reduced capacity (not less than 75% capacity) because the battery is too warm. To reach 100% capacity, a battery must be cooled to below 45°C. |
A deeply discharged battery is one that has been discharged to less than 3.0 volts. When the charger detects a deeply discharged battery, it automatically enters recovery mode, which charges the battery using a reduced current. A red LED indicates recovery mode. If recovery is successful, the charger exits recovery mode and charges the battery to capacity. If the battery cannot be recovered in less than 30 minutes, the red LED turns off and charging stops.
Caution! Remove DC power and remove batteries when installing the charging module.
Power LED off. |
DC power fault - check connection to power supply. Ensure PS51 power supply is connected to an AC power source. |
Charge status LED does not illuminate. |
Battery is not fully inserted. |
Battery does not charge |
Battery discharged below 3.0 volts. Try another battery. |
Up to 2 rechargeable Li-Ion batteries (SB900)
50%=1 hour; 100%=3 hours
-18°C (0°F) to +40°C (104°F)
0°C (32°F) to 60°C (140°F)
-29°C (-20°F) to 74°C (165°F), without batteries
44 x 86 x 116 mm (1.8 x 3.4 x 4.5 in.), H x W x D
425 g (15.0 oz.), without batteries or PS51 External Power Supply
Cast and extruded aluminum
5.5 V DC, 2.72 A
Conforms to electrical safety requirements based on IEC 60065.
c UL us listed by Underwriters Laboratories, Inc.
Authorized under the verification provision of FCC Part 15B.
Meets essential requirements of the following European Directives:
Note: Please follow your regional recycling scheme for batteries and electronic waste
Please follow your regional recycling scheme for battery disposal.
The CE Declaration of Conformity can be obtained from Shure Incorporated or any of its European representatives. For contact information please visit www.shure.com
The CE Declaration of Conformity can be obtained from: www.shure.com/europe/compliance
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: +49-7262-92 49 0
Fax: +49-7262-92 49 11 4
Email: info@shure.de